What are various Pressure calibrators and how to use them?

Pressure calibrators are essential devices used to measure and calibrate pressure measurement instruments, such as pressure gauges, sensors, transmitters, and transducers. These calibrators ensure that pressure measurement devices are accurate and reliable, which is critical in industries like oil and gas, manufacturing, healthcare, and HVAC systems. There are different types of pressure calibrators, each suited to specific applications.

Types of Pressure Calibrators:

  1. Pneumatic Pressure Calibrators:

    • Use: These use air or gas to generate pressure. They are commonly used for low to medium-pressure ranges.
    • Application: Ideal for calibrating pressure sensors in industries like HVAC, pneumatics, and laboratories.
  2. Hydraulic Pressure Calibrators:

    • Use: These use fluids (like oil or water) to generate high pressures.
    • Application: Used for high-pressure calibration, often in heavy industries like oil and gas, and manufacturing.
  3. Digital Pressure Calibrators:

    • Use: These are electronic devices with digital displays that measure and record pressure accurately.
    • Application: Widely used for field and laboratory calibration due to their high precision and easy readability.
  4. Handheld Pressure Calibrators:

    • Use: Portable devices that are typically battery-powered, combining pressure generation and measurement.
    • Application: Used in the field for on-the-go pressure testing and calibration, often in remote locations or for quick checks.
  5. Pressure Comparator/Deadweight Tester:

    • Use: These calibrators generate pressure by applying known weights to a fluid medium. They are one of the most accurate forms of pressure calibration.
    • Application: Mainly used in laboratories for extremely precise calibrations of high-end pressure instruments.
  6. Pressure Modules:

    • Use: Modular devices that can be added to multifunction calibrators or process calibrators to extend their pressure range.
    • Application: Often used in process industries to calibrate various instruments with different pressure ranges.

How to Use Pressure Calibrators:

  1. Select the Appropriate Calibrator:

    • Choose a calibrator based on the pressure range and type of instrument you are calibrating. Ensure the pressure calibrator has a greater accuracy than the instrument being calibrated.
  2. Connect the Calibrator to the Device Under Test (DUT):

    • Securely connect the calibrator to the pressure sensor or gauge using the appropriate fittings, ensuring a leak-free connection.
  3. Generate the Pressure:

    • For pneumatic or hydraulic calibrators, use the pump or pressure source to generate the required pressure. For digital calibrators, apply pressure electronically or manually.
  4. Adjust the Pressure to the Desired Value:

    • Gradually increase or decrease the pressure to reach the desired test point. Many calibrators allow for fine pressure adjustments for more accurate readings.
  5. Record Readings:

    • Compare the pressure reading on the device under test (DUT) with the calibrator's reading. If discrepancies are found, adjust the DUT accordingly.
    • In digital calibrators, the readings may be logged automatically.
  6. Perform Calibration Across Different Points:

    • Calibrate the device at various points across its operational range, such as 0%, 25%, 50%, 75%, and 100% of the full scale, to ensure linearity.
  7. Document the Calibration:

    • After completing the calibration, document the results, including the calibration range, date, and any adjustments made. Calibration certificates can be generated if required for compliance.
  8. Post-Calibration Check:

    • Once calibration is complete, perform a final check by reapplying pressure to ensure the accuracy has been corrected.

Safety and Tips:

  • Ensure Cleanliness: Contaminants in pressure calibrators can cause inaccurate readings, especially in hydraulic systems. Keep equipment clean and dry.
  • Check for Leaks: Inspect all fittings and hoses for leaks before and during calibration.
  • Use Proper Fluid: For hydraulic calibrators, use the manufacturer-specified oil or fluid to prevent damage.
  • Temperature Sensitivity: Be mindful that temperature changes can affect pressure readings. Calibrate in a controlled environment when possible.

Pressure calibrators ensure the reliability and accuracy of pressure measurement devices, which is crucial for safety, efficiency, and compliance in many industries.

Comments

Popular posts from this blog

The Pillars of Precision: Ensuring Quality with Nagman Instruments

 In today's world, accuracy and reliability are paramount across various industries. From ensuring the safety of critical infrastructure to maintaining the quality of everyday products, test and measuring instruments play a vital role. At Nagman Instruments , we understand the importance of these tools and are dedicated to providing you with the instruments you need to achieve consistent, high-quality results. A Diverse Range for Diverse Needs We offer a comprehensive selection of test and measuring instruments catering to a wide spectrum of applications. Whether you're an engineer, technician, researcher, or quality control professional, we have the tools to empower your work.  Here's a glimpse into our instrument categories: Electrical Testers: Measure voltage, current, resistance, and other electrical parameters with our selection of multimeters, clamp meters, and insulation testers. Mechanical Gauges: Ensure dimensional accuracy with our lineup of calipers, micrometers,...

What is a Dead Weight Tester & How it works?

Every business that uses pressure instruments to monitor fluid and gas pressures and flow rates relies on accurately calibrating today's high-tech pressure measurement instrument s. Pressure is a complex measurement discipline. And to have precise measurements, pressure gauge calibration is necessary. That's where pressure calibrators come in. There needs to be a calibration kit for pressure gauges that is universally suitable for all users' needs. Pressure gauge calibration standards diverge substantially based on their uses and the setting in which they are utilized. That’s why there are different types of pressure calibrators for different scenarios. For example, a dead weight tester, multifunction calibrator, or measuring gauge with a predefined accuracy can examine the accuracy of transmitters, sensors, transducers & pressure gauges. Today, we will review what these dead-weight testers are and how they work. Deadweight Testers - What are They? The DWT -...

Economy Pneumatic Pressure Calibrator

At Nagman, you can find a wide range of calibrators that meet the needs of today’s industry. This MPCE-P Selectable Engineering Pressure Units with Ranges from -0.85 to 2 & upto 60 bar and Accuracy ±0.1% F.S., DC Current Measurement as 0 to 25 mA (Active) with Switch Test capability & Zero Offset facility